User`s manual

15
7) Once the Cool Down Cycle is completed the Phase 7 OPL microprocessor controller (computer)
will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for amount set in
Audio Alert On Time). The L.E.D. display will read “WRINKLE GUARD.” The times are fixed
at 2 minutes OFF, 2 minutes ON for a maximum time of 99 minutes. These times are not
programmable. During the ON time, the blower (fan) and the basket (tumbler) will start to rotate
(without heat for 2 minutes). The Phase 7 OPL microprocessor controller (computer) will repeat
this process until the Maximum Wrinkle Guard On Time has expired (99 minutes). The L.E.D.
display will then read “CYCLE DONE” and lockout the dryer functions until the doors are opened.
It will then return to “READY.”
2.
Manually Loaded Cycles
a. Automatic Drying Cycle (Patent No. 4,827,627)
1) L.E.D. display reads “READY” (no cycle in progress).
2) Press AUTO key.
3) L.E.D. display will now read ENTER DRY TEMP 160 TO 200. (Defaults to 160° F [71° C]).
Enter the temperature desired (from 160º F to 200º F [71º C to 93º C] in one-degree increments).
I.E., for 180º F (82º C), press key “1,” key “8,” key “0,” and then press the “START/ENTER”
l
key to accept the value.
4) L.E.D. display will now read ENTER DRY LEVEL finishing, dry, and extra dry. Enter the amount
of extraction (dryness level desired). Finishing has the most moisture content to extra dry, which
has little or no moisture content.
5) L.E.D. display will now read “REVERSE MODE” (defaults to ON). The ON/OFF selection can
be toggled with the “UP ARROW” and “DOWN ARROW.” Once selected, press the “START/
ENTER”
l
key to accept selection.
NOTE: In addition to entering a value by pressing the number keys, the “UP ARROW” and “DOWN
ARROW” can be used to scroll to the number desired or toggle between selections.
6) At the start of a cycle the L.E.D. display will initially display the cycle parameters of the selected
cycle, AUTO DRYING CYCLE, TEMP 180, DRYNESS LEVEL EX DRY. Then the display will
read AUTO CYCLE, ELAPSED TIME 00:00 MINUTES. The L.E.D. display will continue to
show AUTO CYCLE, ELAPSED TIME XX:XX MINUTES until the load is dried to the appropriate
dryness level.
NOTE: Press and hold the “UP ARROW” to view the basket (tumbler) temperature at any time.
NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR”
O
key, at this time the
dryer will go into a cycle pause. If the “STOP/CLEAR”
O
key is pressed again at this point,
the cycle that was in progress will be cancelled and returned to the “READY” state.