IMPORTANT NOTES
The start of the batch disables the following function:
- Reverse totalizer : visualization and pulse emission
- Reset reverse totalizer (page 51 pos. 32-33)
- Lock totalizer (page 51 pos. 34)
- Energy saving (page 48 pos. 23)
- Data logger (page 57 menu 9)
- Calibration (page 47 pos. 21, page 51 pos. 35)
To optimize the performances of meter used like a batch instrument, it is recommended to set them as close as
possible to the of plant, choosing the opportune values of time constant (pos. 17) and acceleration threshold (pos. 18).
START/STOP BATCH:
- From remote input (page 26)
- From key on the keyboard.
The remote input and the button on the keyboard have the follwing function:
SHORT PRESSING/PULSE INPUT =
START (on display appears the batch in progress symbol: )
STOP (on display disappears the batch in progress symbol: )
After a stop during a batch, is possible:
- Keyboard
Start the batch from interrupting point
Reset the active batch: long pression of key and key
- Remote input (see page 26)