Technical information

C:
\
UFFICIO TECNICO
\
MANUALI
\
ML2
00
\
ML200 INGLESE
\
23
For the sensors MS 500-1000-2500, in the cases listed below, see the following instruction:
If the sensor must be install in the piping with a
chatode protection, some precautions should be
taken:
1) Grounding metallic rings should be pr
ovided to
ground the liquid
2)
the sensor should be insulated from the piping,
using gasket between the rings and the sensor
and insulating bushes for the tightening tie
rods.
The flanges pipe should be connected one to
the other (by-passing the sensor) with a
copper plait 6 mm
2
section.
If the sensor has to be mounted on a pipe made of
an insulating material, then for grounding purposes of
the liquid there are two possibility:
Install two metallic ring (available on request)
between the sensor flange
s and the counter flanges of
the pipe line; or:
Use a sensor with the additional grounding electrode.
ISOIL
METALLIC RING
INSULATING GASKET
ISOIL
METALLIC RING
INSULATING GASKET
INSULATING BUSH