Technical information

C:
\
UFFICIO TECNICO
\
MANUALI
\
ML2
00
\
ML200 INGLESE
\
10
- Weld to the pipeline a pipe Ø 1".
ATTENTION: verify "X" dimension
(pic. 2).
Pic. 1
Pipe Ø 1"
Pipe line
Spanner 40mm
Screw the valve Ø 1" to the welded pipe
X
Xmax=140mm
- Screw the 1" jacket to the valve
ATTENTION: the O-Ring in the
jacket must be place underside
(near valve)
Inferior estremity of
the jacket
(O-Ring seal)
- Insert the sensor at
close valve
- Tighten the fixing nut
with spanner (pic. 6)
- Open the valve
- Screw the sensor
up to "Z" dimension
- Verify the line up
(pic. 9)
- Tighten the block
nut manteining the
aligment
flow
direction
Pic. 2
Pic. 3
Pic. 4
Pic. 5
Pic. 6
Pic. 7
Pic. 8
Pic. 9
Z
Block
nut
N.B.: Le maniglie di inserimento
del sensore sono removibili
sensor
handles
1
2
3
4
5
Fixing nut
Fixing
nut
MS 3700 Assemble Instructions