Installation manual
36
K. COMPRESSED AIR REQUIREMENTS
The model ML-190 dryer requires an external supply of compressed air (2.5 cfh at 80 PSI [0.07 cmh at 5.51
bars] for gas models and 3.25 cfh at 80 PSI [0.09 cmh at 5.51 bars] for steam models). For steam models,
compressed air is necessary for the air operated steam damper. On both the steam models as well as the gas
models, compressed air is necessary/required for blower air jet operation...to clean lint from the impellor/fan
(squirrel cage).
1. Air Requirements
a. Microprocessor Controller (Computer) Dryers...
2. Air Regulation
a. No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51
bars) must be provided. It is suggested that a filter/regulator/gauge (F/RG) arrangement be added to
the compressed air line just before the dryer connection. This is necessary to insure that correct and
clean air pressure is achieved.
3. Air Connection
a. Air connection to this system is an 1/8” F.P.T. (female pipe thread) as per the illustration below.
Compressed Air Supply Air Pressure
Normal 80 PSI 5.51 bars
Minimum Supply 70 PSI 4.82 bars
Maximum Supply 90 PSI 6.20 bars
Shaded areas are stated in metric equivalents