Specifications
338
COMMUNICATIONs
TRUSTED
SINCE
18 62
USA CANADA INT’L
FAX 800.451.2632 FAX 800.524.2853 FAX +1.815.397.9247
PHONE 800.435.0786 PHONE 866.384.8813 PHONE +1.815.397.7070
Wire and Valve Locator
• Adjustabletransmitpowerallowsyoutoselectthebestsignalformaximum
performance.
• Transmitter’shighpoweroutputoffersextendedrangeanduseonhigher
resistancewirepathsthatotherlocatorscan’ttouch.
• Receiverprovidesbothaudibleandvisualindicationsofsignalstrength.
• Lightweightreceiverwandmakesiteasyforyoutomovealongquickly
tolocateeventhelongestwirepath.
• Ruggedheadphonesblockambientnoiseandimprove“feel”forthesignal.
• Includestransmitter,receiver,headset,groundstake,andcompleteinstructions.
• Battery-operated:(8)“D”Cellsand(1)9V.
SPECIFICATIONS
Power Requirements
Transmitter:(8)
“D”Cell;
Receiver:(1)9Vbattery
Battery Life Transmitter:50hoursnominal
Receiver:100hoursnominal
Transmitter Frequency 1748Hz
Transmitter Power 750Vp-p 285Vrms
Voltage Protection 120VAC/250VDC
Construction Powder-coatedaluminumhousinginpolyethylenecase
Case Dimensions 33.5"x8.25"x3.75"
Weight 12lbs.complete
CAT. NO. UPC NO. DESCRIPTION
521A 86788 Wire and Valve Locator
521A-R 12623 Receiver
HS1 08695 Headset
GS1 60362 GroundStake
Locators Application Guide
1. 10,000 ohms and less–both ends isolated from grounds.
2. Does not locate the path–has to be predetermined and only in direct burial applications. 5,000,000 and less.
3. Transmitter connected to metallic shield.
4. Will trace coax providing the bOnd is in place at the remote end–will disrupt service.
5. No sorting (high RF bleeds) can trace coax if transmitter connected to braid.
6. Low frequency locators need a “path to earth” (dirt), 5000 ft. on an open conductor and 2500 ft. on a metallic pipe at 3 ft. deep
FEATURE
BLL-200 501 PE2003 508S 521A
Traceconcealedwiringinwallsandfloors • •
Locatejunctionboxrelaysandtransformers •
Locateswitchgear •
Findshortstoground •
2
•
1
TracewiresinPVC(nonmetallicconduit) • • •
Find opens in a circuit •
Localizepowerandlightingpanels • • •
Operateonenergizedcircuits • • •
Operate on telecom circuits • • • •
Operateonpowercircuits(600VAC) •
Operateonunenergizedcircuits • • • • •
Traceshieldedcable • •
3
•
3
•
3
Trace buried metal conduit
Tracecoaxcable • •
5
•
5
•
4
Autogaincircuitryforimprovedaccuracy •
AC voltage range 0-600V 0-240V 0-240V 0-240V 0-120V
DC voltage range 0-300V 0-500V 0-400V 0-500V 0-250V
Distance–receiverfromtransmitter 5,000ft. •
7
5000ft. 1000ft. •
6
Transmitter battery (4)AA (8)AA 12V
rechargeable
(1)9V (8)D
Receiverbattery (4)AA (1)9V (1)9V (1)9V (1)9V
7. Direct Connection 4,000 ft at 7 ft deep
Inductive Coupler 1,000 ft at 3 ft deep
Inductive Antenna 700 ft at 3 ft deep