Specifications

309
USA CANADA INT’L
FAX 800.451.2632 FAX 800.524.2853 FAX +1.815.397.9247
PHONE 800.435.0786 PHONE 866.384.8813 PHONE +1.815.397.7070
www.greenlee.com
= NEw PrODUCT
= rEPLACEmENT PArT = ACCESSOry
B
= BArE TOOL
Station Master Pro
Station Master Pro Kit
CAT. NO. UPC NO. DESCRIPTION
24B 86786 StationMasterPro
CAT. NO. UPC NO. DESCRIPTION
24BK 86787 StationMasterProKit
•Troubleshootirrigationsystems.
•Activateandcyclesolenoids.
•Testsolenoidsforcontinuity.
•Sendtonetoidentifywires.
•Measureclockvoltage.
•Lowbatteryindication.
•Easy-to-understandLEDs.
•TestleadswithBed-of-NailsandpiercingPinClips.
•1-yearlimitedwarranty.
• Troubleshootirrigationsystems.
• Chattermodeforaudiblelocatingofvalves.
• Activateany24VACvalvesolenoid.
• Testsolenoidsforcontinuity.
• Sendtonetoidentifywires.
• CheckclockACvoltage.
• Lowbatteryindication.
• Easy-to-understandLEDs.
• Testleadswith'bed-of-nails'andpiercingpinplips.
• Tracingvalvewiring.
• Locatesundergroundsolenoids.
SPECIFICATIONS
Minimum Voltage for Clock LED 15 VAC
(LEDintensityincreasesasvoltageincreases)
Minimum B attery while Testing 10.5VDC
Maximum Input Voltage between Test Leads 28 VAC
Solenoid Circuit Recharge Time 2.5seconds
Maximum Distance Range to Activate one Solenoid 12AWGLoop3000-13000feet
14AWGLoop2000-8500feet
18AWGLoop500-3000feet
Power Source 9V alkaline batteries
Battery Life 3hourscontinuous
Operating/Storage Temp. 32°F-122°F(0°-50°C)
SPECIFICATIONS
Minimum voltage for clock LED 15 V AC
Minimum battery while testing 10.5VDC
Maximum input voltage between test leads: 28 V AC
Solenoid activate output voltage: 27 to 18 V AC
Battery: 2 - 9V Alkaline batteries
Operating/storage temperature: 32°Fto122°F(0°Cto50°C)
Relative humidity (max): 80%