Technical information
Cuda 12000 IP Access Switch CudaView Administration Guide
Viewing Service Flows 593
Min Reserved Rate
(bits/sec)
Guaranteed minimum rate, in bits/sec, for this
parameter set.
The default is zero indicates no reserved bandwidth.
Min Reserved Packet
(bytes)
Assumed minimum packet size, in bytes, for the
minimum reserved rate.
Active Timeout (secs) Maximum duration, in seconds, that resources
remain unused on an active Service Flow before the
CMTS signals that both active and admitted
parameters are set to null.
The default is zero to indicate an infinite amount of
time.
Admitted Timeout Maximum duration, in seconds, that resources
remain in admitted state before being released. A
value of zero indicates an infinite amount of time.
Max Concat Burst (bytes) Maximum concatenated burst, in bytes, for an
upstream Service Flow. A value of zero indicates no
maximum burst.
Scheduling Type Upstream scheduling service for an upstream Service
Flow.
Request Policy Octets Indicates the transmit interval opportunity the cable
modem omits for upstream transmission request and
packet transmissions.
A value of one indicates the cable modem must not
use an opportunity for transmission.
Nominal Polling Interval
(usecs)
Nominal interval, in microseconds, between
successive unicast request opportunities on an
upstream Service Flow. This value is zero if this
parameter does not apply to the scheduling type of
the QoS parameter set or if the value is unknown.
Tolerable Poll Jitter
(usecs)
Maximum amount of time, in microseconds, that the
unicast request interval delays from the nominal
periodic schedule on an upstream Service Flow.
Unsolicited Grant Size
(bytes)
Unsolicited grant size, in bytes. It includes the entire
MAC frame data PDU from the Frame Control byte
to end of the MAC frame.
Nominal Grant Interval
(usecs)
Nominal interval, in microseconds, between
successive data grant opportunities on an upstream
service flow.
Table 20-13 Parameter Set Window Parameters (continued)
Parameter Description