Technical information
Cuda 12000 IP Access Switch CudaView Administration Guide
Configuring Advanced CMTS Functions 527
4. Click the Flap Control tab. The Flap List Control window appears.
5. Enter values for the parameters. Refer to Table 18-18.
6. Click Apply to commit the configuration; or, click Reset to set the fields
to the default values.
What You See
Figure 18-19 Flap List Control Window
Parameter Descriptions
This table describes the parameters that you configure for Flap Control.
Table 18-18 Flap Control Parameters
Parameter Description
Max Table Size: (rows) Specify the maximum number of entries (cable
modems) in the flap list. By default, the table size is
set to 8192. Acceptable values are 0 to 8192.
Aging Threshold: (days) Specify the number of days to age the cable
modem from the flap list table. By default, aging is
set to 60 days. Acceptable values are 1 to 60 days.
Note that setting the aging threshold to zero results
in cable modems never being aged from the table.