Configuring Hardware Alarms 289
What You See
Figure 11-12 Fan Supply Assertion Levels Window
Configuring the Power Assertion Level
You must configure the assertion level that the attached devices use when
indicating a fault condition. You must verify the assertion level used by the
attached power supplies and set the AC-monitor, DC-monitor, and power
supply temperature assertion levels accordingly. To set the power assertion
levels, follow this procedure:
1. In the Hardware Alarm Configuration window, click the Power Supply
Assertion Levels tab.
2. Select the proper fault level for the Temp, AC, and DC options. The signal
that the device sends can use one of these assertion levels:
Active High Signal indicates the assertion state as a logic ONE state.
Active Low Signal indicates the assertion state as a logic ZERO
state.
3. Click Apply to commit the changes or click Reset to exit without saving.
4. Click Refresh to update the information.