Technical information

ADC Telecommunications, Inc.
220 C
HAPTER 9: MODULE ADMINISTRATION
Viewing Gigabit Ethernet Interfaces
You may view summary information for all the Gigabit interfaces installed on
your Cuda 12000.
To view summary information, follow this procedure:
1. Navigate to the Gigabit folder.
2. Click the Summary tab. The Interface Summary window appears. (Refer
to Figure 9-10.)
Interface Summary Window
The Interface Summary window displays all the Gigabit interfaces installed
on the Cuda 12000.
This table describes the Gigabit Interface Summary window parameters.
Table 9-12 Gigabit Module Summary Window Parameters
Parameter Description
Chassis Unique ID you assigned to the chassis
Slot Number of the physical chassis slot in which the module
resides. For information on how slots are numbered, see the
Cuda 12000 IP Access Switch Installation Guide.
Interface Number of this physical interface on the module.
Type Indicates the type of Ethernet link.
Interface Status Indicates that you have a valid link (connection) on that
interface. Up indicates a valid link is established; down
indicates there is no link on that interface.
Admin Status Online status of this physical interface. Indicates whether the
module is up (online) or down (offline).