Technical information

ADC Telecommunications, Inc.
200 C
HAPTER 9: MODULE ADMINISTRATION
Configuring the POS Clock Source
The Cuda 12000 allows you to configure the POS module as the clock source
for the primary clock (A) and secondary clock (B), which are contained on the
backplane.
If you use a POS module as the clock source, make sure that the interface on
the POS module has been configured to receive clocking from the other
(remote) side of the POS link. Refer to Chapter 10, Packet Over SONET
Administration for more information on configuring POS interfaces.
The following table describes the Card Drive Clock configuration parameters:
Ta b l e 9- 4 Card Drive Clock Parameters
To configure the POS module as the clock source, follow this procedure:
1. Navigate to the Card Summary folder.
2. Click the Card Summary tab. The Card Summary window appears.
(Refer to Figure 9-2.)
3. Refer to the Card Type column to find the POS module, which is listed as
forwarderOC3 or forwarderOC12.
4. Select the row that includes the POS module.
5. Click the Clock Synchronization tab. The Clock Synchronization
window appears. (Refer to Figure 9-3.)
Parameter Description
Card Drive Clock A Refers to the primary clock (A) on the backplane.
Configuration options are:
notSupported
Enabled
Disabled
Card Drive Clock B Refers to the secondary clock (B) on the backplane.
Configuration options are:
notSupported
Enabled
Disabled