Technical information
Cuda 12000 IP Access Switch CudaView Administration Guide
Configuring SNMP Notifications 163
Modifying an SNMP Notification
Follow this procedure to modify an SNMP notification:
1. In the Notifications window, select the notification you wish to modify
and click Modify. The Modify Notification window appears.
2. Update the necessary information. Refer to Table 7-15.
3. Click Ok to commit the changes or click Cancel to exit without saving.
Timeout Amount of time that passes before it is assumed the host did
not receive the notification message.
Retries When the notification type is set to Inform, the Retries
parameter indicates the number of retries made when a
response is not received for a generated message. The range
is 0 to 255 and the default is 3.
Max. Message
Size
Maximum message size of an SNMP message that the SNMP
engine transmits or receives and processes.
Security Model Security model that processes SNMP messages. The options
are V1, V2c, or V3.
Security Level Minimum level of security to necessary to gain access rights.
The options are: NoAuth (no Authentication), Auth
(Authenticated), and Priv (encryption). The default is NoAuth.
Group Name Name of the associated group.
Storage Type Storage type for this group.
Volatile Entry is stored in volatile memory. The information is lost
during a system reboot.
Non-volatile Entry is stored in non-volatile memory. The information is not
lost during a system reboot.
Permanent Entry is stored in non-volatile memory. You cannot delete the
information but you can make modifications.
Read-only Entry is stored in non-volatile memory. You cannot delete or
modify the information.
Parameter Description