Technical information

Cuda 12000 IP Access Switch CudaView Administration Guide
Configuring SNMPv3 Users 139
Parameter Descriptions
This table provides a description of the Modify User window parameters
Ta b l e 7- 7 SNMPv3 Modify User Window Parameters:
Parameter Description
User Name Name of the user. Range is 1 to 32 characters.
Authentication Type Enables you to select the authentication type used to
authenticate the user.
Authentication
Password
Password key for authentication. If the authentication
type is HMAC-MD5-95 or HMAC-SHA-96, you must
enter a password for authentication. The password
must be an ASCII Hex string with a maximum size of 40
characters (20 bytes).
Password is write-only for security purposes. You must
enter the password each time you make a modification.
Privacy Type Encrypts data for privacy according to the DES
algorithm.
Privacy Password Password for the privacy type. The password must be
an ASCII Hex string with a maximum size of 64
character (32 bytes).
Storage Type Storage type for this entry.
Volatile Entry is stored in volatile memory. The information is
lost during a system reboot.
Non-volatile Entry is stored in non-volatile memory. The information
is not lost during a system reboot.
Permanent Entry is stored in non-volatile memory. You cannot
delete the information but you can make modifications.
Read-only Entry is stored in non-volatile memory. You cannot
delete or modify the information.
Entry Status Allows you to enable or disable an entry.
Active Actives an entry.
Not In Service Allows you to temporarily disable the entry.