Technical information
ADC Telecommunications, Inc.
116 C
HAPTER 5: CHASSIS MANAGEMENT
Configuring Traffic Relay
The traffic relay function configures processes, such as the HTTP server, to
send and receive TCP or UDP packets using an internal address on the Cuda
12000, for in-band management. For example, you can enable forwarding
of Telnet traffic and HTTP traffic using an internal address, thereby allowing
you to perform in-band management of the Cuda 12000 using the CLI or
CudaView.
To enable or disable traffic relay options, follow these procedures:
1. Navigate to GroupName>ChassisName> Cuda Chassis Manager >
Configuration > Chassis Configuration.
2. Click the Traffic Relay tab.
3. For each server, select Enable option and enter the destination port
number to enable the relay of UDP/TCP traffic in the Cuda 12000.
4. To disable the traffic, clear the option.
5. Click Apply to commit the information.
6. Click Refresh to update the information.