Installation guide
Table Of Contents
- About This Guide
- Hardware Overview
- Preparing for Installation
- Rack-Mounting the System
- Installing Modules
- Cabling the System
- Powering On and Powering Off
- Configuring Network Access
- System Specifications and Compliance
- Martek Power Supply
- Wiring Diagrams
- Glossary
- Index

Cuda 12000 IP Access Switch Installation Guide
Application Modules 47
Table 1-7 shows the available configurations and associated parameters of
OC-12 modules.
Table 1-7 OC-12 Configurations
In addition to the common module components found on each application
module, each POS SpectraFlow module includes an LED display that provides
these port status:
Figure 1-13 shows a POS SpectraFlow module. For a description of each
numbered callout, see Table 1-2 on page 26.
Fiber Type
Diameter
(microns)
Wavelength
(Nanometers)
Transmission
Distance
Optical
Output Power
Input
Sensitivity
Multi mode 62.5 1300 500 meters ■ Min: -20 dBm
■ Max: -14 dBm
■ Min: -26 dBm
■ Max: -14 dBm
Single
mode
9 1300 15 kilometers ■ Min: -15 dBm
■ Max: -8 dBm
■ Min: -28 dBm
■ Max: -7 dBm
Single
mode
9 1300 40 kilometers ■ Min: -5 dBm
■ Max: 0 dBm
■ Min: -34 dBm
■ Max: -8 dBm
Status Description
ACTIVITY Indicates a packet is transmitting from, or received to the
module.
BER (Bit Error Rate) Indicates the BER threshold has been exceeded.
LOF (Loss of Frame) Indicates a loss of frame condition has occurred.
SIG DET (Signal
Detect)
Indicates a valid signal. Illuminates when optical energy is
detected.