Installation guide

Table Of Contents
ADC Telecommunications, Inc.
46 C
HAPTER 1: HARDWARE OVERVIEW
Packet Over SONET (POS) SpectraFlow Modules
The system supports transmission of IP data directly over Synchronous
Optical Network (SONET) to more efficiently utilize bandwidth and leverage
the management, fault-tolerance, and high transmission speeds inherent in
SONET networks.
The system supports connection to SONET networks using these modules:
POS modules connect to the network using the provided fiber-optic cable.
This fiber optic cable consists of a duplex SC connector on one end and an
AMP MPX connector on the other end. The module is connected to the
network by installing a fiber module backplate on the selected slot, then
inserting the AMP MPX connector into the blind-mate fiber port located on
the backplate. Cabling to the backplate and not to the module itself allows
you to remove and replace the module without re-cabling. It also allows you
to cable slots in advance.
Both OC-3 and OC-12 POS modules are available in a number of
configurations. Table 1-6 shows the available configurations and associated
parameters of OC-3 modules.
Table 1-6 POS OC-3 Configurations
POS Module Description
POS OC-3 Provides a 155 Mbps connection to SONET STS-3c or SDH
STM-1 networks.
POS OC-12 Provides a 622 Mbps connection to SONET STS-12c or
SDH STM-4 networks.
Fiber Type
Diameter
(microns)
Wavelength
(nanometers)
Transmission
Distance
Optical
Output Power
Input
Sensitivity
Multi mode 62.5 1300 2 kilometers Min: -20 dBm
Max: -14 dBm
Min: -31 dBm
Max: -14 dBm
Single mode 9 1300 15 kilometers Min: -15 dBm
Max: -8 dBm
Min: -31 dBm
Max: -8 dBm
Single mode 9 1300 40 kilometers Min: -5 dBm
Max: 0 dBm
Min: -34 dBm
Max: -8 dBm