Installation guide

Table Of Contents
Cuda 12000 IP Access Switch Installation Guide
Application Modules 43
Gigabit Ethernet SpectraFlow Modules
The system supports connection to Gigabit Ethernet networks using these
modules:
These modules connect to the network using an ADC-provided fiber-optic
cable. This fiber optic cable consists of a duplex SC connector on one end
and an AMP MPX connector on the other end. Connect the module to the
network by installing a fiber module backplate on the selected slot, then
inserting the AMP MPX connector into the blind-mate fiber port located on
the backplate. Cabling to the backplate and not to the module itself allows
you to remove and replace the module without re-cabling. It also allows you
to cable slots in advance.
These single-port modules comply with IEEE 802.3z specifications. Table 1-4
shows the transmission ranges for the 1000BASE-SX modules.
Table 1-4 1000BASE-SX Transmission Ranges
Table 1-5 shows the transmission range for the 1000BASE-LX modules.
Gigabit Ethernet
Module
Description
1000BASE-SX Provides a 1000 Mbps Ethernet connection over 62.5 or
50 micron multi mode fiber-optic cable.
1000BASE-LX Provides a 1000 Mbps Ethernet connection over 9 micron
single-mode fiber-optic cable and supports a transmission
distance of up to 10 kilometers or more.
Fiber Type
Diameter
(microns)
Wavelength
(Nanometers)
Transmission
Distance
Optical
Output Power
Input
Sensitivity
Multi mode 50 850 500 meters Min: -9.5 dBm
Max: -4 dBm
Min: -17 dBm
Max: 0 dBm
Multi mode 62.5 850 220 meters Min: -9.5 dBm
Max: -4 dBm