140 A
PPENDIX B: SYSTEM SPECIFICATIONS AND COMPLIANCE
Upstream CMTS RF
Interfaces
■ DOCSIS 1.0/1.1
■ Frequency range: 5–42 MHz
■ Modulation: QPSK or 16 QAM
■ Information rate: 320 Kbps – 10 Mbps
Power Requirements
■ Voltage DC: –48V (–42 to –68)
■ Max Watts = 1100
■ Amperage = 23 @ -48V
Environmental
■ Temperature: 0 – 40° C
Safety ■ UL 1950 Third Edition
■ CSA C22.2 No. 950
■ EN 60950
Electromagnetic (EMC)
■ FCC Part 15, Class A
■ EN 55022 Class A
Protocols and Routing
■ Ethernet
■ RIPv1
■ RIPv2
■ OSPFv2
■ Policy-based Route Filters
Provisioning/Directory
Services
■ DHCP, TFTP, DNS/DDNS, SysLog, and Time servers
■ LDAP client & LDAP server
■ Dynamic creation of CM configuration files
Security
■ DOCSIS Baseline Privacy (BPI), BPI+
■ CM and username/password authentication
■ Secure remote administration
Network Management
■ Craft Interface: 10/100BASE-TX
■ Web/Java-based graphical user interface (GUI), SNMP
■ MIBs: SNMP, ADC Cuda
■ CLI: Craft port and telnet
Software Load
Capabilities
■ Multiple software versions stored within system
■ Software updates via FTP