Installation guide

Table Of Contents
Cuda 12000 IP Access Switch Installation Guide
131
Powering Off the System
Use this procedure to properly power off the system:
1. Log on to the Linux operating system with the following login
information:
Account Name: root
Password: bas
2. Run halt.
3. After a few minutes, the LED display(s) on the module(s) will display
Stopped.
4. Move the top power source (A) switch, located in the lower-right front of
the chassis, to the off position.
5. If you have connected to a second power source, move the lower power
source (B) switch, located in the lower right-front of the chassis, to the off
position.
Management
Module
SC Down Displayed after issuing the ccdown command from
the CLI. Indicates all Management module
components have safely shut down.
Management
Module
SC Reset Displayed after issuing a reset command for the
Management module from the CLI. Indicates that
the Management module will safely shut down
and then reset.
Table 6-2 Boot Error Messages (continued)
Module Type
Operational
Status Indication
Description