Cuda 12000 IP Access Switch Installation Guide
Understanding the Initialization Process 129
Packet Over SONET (POS)
OC-3 SpectraFlow Module
OC3
OC3.
OC3rs
■ When displayed immediately before
Init, signals start of software
control. Indicates module supports
OC-3 media.
■ When displayed after Init, this
message indicates that the module
is operational without error.
■ The OC3 message followed by a
period—”.”—indicates a software
crash has occurred; the module
resets itself. Contact ADC Customer
Support.
■ When appended with rs, indicates
that ADC has configured the
module as the system’s route server.
The module operates in both a
forwarding and route server
capacity.
Packet Over SONET (POS)
OC-12 SpectraFlow
Module
OC12
OC12.
OC12rs
■ When displayed immediately before
Init, signals start of software
control. Indicates module supports
OC-12 media.
■ When displayed after Init, this
message indicates that the module
is operational without error.
■ The OC12 message followed by a
period—”.”—indicates a software
crash has occurred; the module
resets itself. Contact ADC Customer
Support.
■ When appended with rs, indicates
that ADC has configured the
module as the system’s route server.
The module operates in both a
forwarding and route server
capacity.
DOCSIS/EuroDOCSIS
Modules
CMTS Displayed immediately before Init,
signals start of software control.
Indicates module is a DOCSIS or
EuroDOCSIS module.
Table 6-1 Module Initialization Phases (continued)
Module Type Message Description