Technical information

ADC Telecommunications, Inc.
80 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
chassis-fault
Enables Cuda 12000 chassis alarms. The no form of the command disables these alarms.
Mode
root
Syntax
chassis-fault [backplane] [backplane-power] [backplane-power-a]
[backplane-power-b] [backplane-temp] [bits-a] [bits-b] [blue]
[fan-rotation] [fan-temp] [local-pwr-a] [local-pwr-b]
[processor-temp] [ps-ac] [ps-dc] [ps-temp] [red-alarm] [yellow]
no chassis-fault [backplane] [backplane-power] [backplane-power-a]
[backplane-power-b] [backplane-temp] [bits-a] [bits-b] [blue]
[fan-rotation] [fan-temp] [local-pwr-a] [local-pwr-b]
[processor-temp] [ps-ac] [ps-dc] [ps-temp] [red-alarm] [yellow]
Arguments
backplane Enables the alarm that generates when a module asserts a backplane
system fault condition. The no form of the command disables the
alarm.
backplane-power Enables the alarm that generates when one or more modules detect
an internal power fault. The no form of the command disables the
alarm.
backplane-power-a Enables the alarm that generates when one or more modules detect a
Power_A (48V) fault. The no form of the command disables the
alarm.
backplane-power-b Enables the alarm that generates when one or more modules detect a
Power_B (48V) fault. The no form of the command disables the alarm.
backplane-temp Enables the alarm that generates when one or more modules detect a
temperature fault. The no form of the command disables the alarm.
bits-a Enables the alarm that generates when chassis management software
detects loss of the BITS-A clock. The no form of the command
disables the alarm.
bits-b Enables the alarm that generates when chassis management software
detects loss of the BITS-B clock. The no form of the command disables
the alarm.