64 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
aux-device fan-temp
Sets the assertion level of the signal that reports fan temperature faults to the management
module.
Mode
root
Syntax
aux-device fan-temp fault-level {active-high | active-low}
Arguments
Example
cli:root# aux-device fan-temp fault-level active-high
cli:root# show aux-device fan-temp
Assert Fan Temp Fault active-high
Related Commands
aux-device ac-monitor on page 55
aux-device backplane-clock-a on page 56
aux-device backplane-clock-b on page 57
aux-device db15 alarm on page 58
aux-device dc-monitor on page 62
aux-device fan-rotation on page 63
aux-device ps-temp on page 65
chassis-fault on page 80
show aux-device on page 376
{active-high |
active-low}
Specifies one of the following assertion levels:
active-high – The signal reports the assertion state as a logic one state.
active-low (the default) – The signal reports the assertion state as a logic
zero state. Change to active-high only if the fan uses an active high
signal to indicate a fault.