Technical information

Cuda 12000 IP Access Switch CLI Reference Guide
trace-log 589
Arguments
Within slot mode:
Within cable interface mode:
<sw-component-id> The ID of the software component that you want to
monitor. These IDs are listed in Table 2-4.
<log-level> The software component's trace logging severity level.
One of the following:
highest
high
medium
low
cm mac-address <cm-mac-address> Specifies the MAC address of the modem that
you want to monitor.
ranging {true | false} Enables and disables the monitoring of messages
that occur during the ranging stage.
registration {true | false} Enables and disables the monitoring of messages
that occur during the registration stage.
baseline-privacy {true | false} Enables and disables the monitoring of messages
that occur during the baseline privacy stage
(applicable only when baseline privacy is
enabled).
detail-level
{highest | high | medium | low}
Specifies the amount of detail: highest, high,
medium, or low.