Technical information

ADC Telecommunications, Inc.
566 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
Table 2- 3 Notification Types
Notification Type Indicates that...
authentication-failure The SNMP entity on the Cuda 12000, acting in an agent role,
has received a protocol message that is not properly
authenticated. This notification type has a “notice” priority.
Refer to the description of the event-config reporting
command for more information on event priorities.
bcm-failover-down FastFlow BPM services are going down. This notification type
has a “notice” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
bcm-failover-up FastFlow BPM services are coming up. This notification type
has a “notice” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
bcm-state-change A change in the IP address configuration of the craft port on
the Cuda 12000 has occurred. This notification type has a
“notice” priority. Refer to the description of the event-config
reporting command for more information on event priorities.
bcm-sw-mismatch The secondary FastFlow BPM will not come up because its
software revision does not match the software revision of the
primary. This notification type has a “notice” priority. Refer to
the description of the event-config reporting command for
more information on event priorities.
cable-modem-auth-failure An unauthorized cable modem attempted to connect to the
system. This notification type has a “notice” priority. Refer to
the description of the event-config reporting command for
more information on event priorities.
cable-modem-down A cable modem has gone down. This notification type has a
“critical” priority. Refer to the description of the event-config
reporting command for more information on event priorities.
cable-modem-up A cable modem has come up. This notification type has a
“notice” priority. Refer to the description of the event-config
reporting command for more information on event priorities.
card-down A card on the Cuda 12000 has gone down. This notification
type has a “critical” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
card-up A card on the Cuda 12000 has come up. This notification type
has a “notice” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.