Technical information
ADC Telecommunications, Inc.
566 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
Table 2- 3  Notification Types
Notification Type Indicates that...
authentication-failure The SNMP entity on the Cuda 12000, acting in an agent role, 
has received a protocol message that is not properly 
authenticated. This notification type has a “notice” priority. 
Refer to the description of the event-config reporting 
command for more information on event priorities.
bcm-failover-down FastFlow BPM services are going down. This notification type 
has a “notice” priority. Refer to the description of the 
event-config reporting command for more information on 
event priorities.
bcm-failover-up FastFlow BPM services are coming up. This notification type 
has a “notice” priority. Refer to the description of the 
event-config reporting command for more information on 
event priorities.
bcm-state-change A change in the IP address configuration of the craft port on 
the Cuda 12000 has occurred. This notification type has a 
“notice” priority. Refer to the description of the event-config 
reporting command for more information on event priorities.
bcm-sw-mismatch The secondary FastFlow BPM will not come up because its 
software revision does not match the software revision of the 
primary. This notification type has a “notice” priority. Refer to 
the description of the event-config reporting command for 
more information on event priorities.
cable-modem-auth-failure An unauthorized cable modem attempted to connect to the 
system. This notification type has a “notice” priority. Refer to 
the description of the event-config reporting command for 
more information on event priorities.
cable-modem-down A cable modem has gone down. This notification type has a 
“critical” priority. Refer to the description of the event-config 
reporting command for more information on event priorities.
cable-modem-up A cable modem has come up. This notification type has a 
“notice” priority. Refer to the description of the event-config 
reporting command for more information on event priorities.
card-down A card on the Cuda 12000 has gone down. This notification 
type has a “critical” priority. Refer to the description of the 
event-config reporting command for more information on 
event priorities.
card-up A card on the Cuda 12000 has come up. This notification type 
has a “notice” priority. Refer to the description of the 
event-config reporting command for more information on 
event priorities.