Technical information
Cuda 12000 IP Access Switch CLI Reference Guide
show snmp notify 531
Example
cli:null:root> enable rootcli:192.168.208.3:root# show snmp notify
row count: 2
Host:Port Storage Notifications Sent Type
-------------------- ----------- --------------------------------------- ----
201.100.1.1:164 NonVolatile cold-start link-up inform
127.0.0.1:54321 NonVolatile docs-init-req-fail docs-init-rsp-fail V2
docs-init-ack-fail docs-dyn-req-fail
docs-dyn-rsp-fail docs-dyn-ack-fail
docs-bpi-init docs-bpkm docs-dynamic-sa
docs-dcc-req-fail docs-dcc-rsp-fail
docs-dcc-ack-fail prov-service
ldap-failed ldap-restored
subnet-addr-low subnet-addr-high
isp-addr-low isp-addr-high
duplicate-addr bcm-failover-down
bcm-failover-up bcm-sw-mismatch
card-down card-up trace-log
cable-modem-up cable-modem-down
bcm-state-change icl-state-change
cable-modem-auth-failure
dhcp-relay-not-configured
local-sonet-alarm remote-sonet-alarm
chassis-fault chassis-fault-cleared
cold-start warm-start link-down link-up
authentication-failure
Note that the 127.0.0.1:54321 host entry is a special entry that CudaView uses to receive
traps from the chassis.
Refer to Table 2-3 on page 566 for descriptions of notifications.
Related Commands
■ show snmp community on page 523
■ show snmp context on page 525
■ show snmp group on page 527
■ show snmp host on page 528
■ show snmp user on page 532
■ show snmp view on page 533