Technical information
Cuda 12000 IP Access Switch CLI Reference Guide
show chassis-fault status 387
show chassis-fault status
Displays which Cuda 12000 chassis alarms are enabled and disabled. Enabled alarms are listed as
“okay.” Disabled alarms are listed as “disabled.” If a fault has caused an alarm to generate, the
status is “faulted.”
Mode
root
Syntax
show chassis-fault status
Example
cli:192.168.244.212:root# chassis-fault backplane-power local-pwr-a
cli:192.168.244.212:root# show chassis-fault status
Chassis Fault Status
Bits A Fault disabled
Bits B Fault disabled
Backplane System Fault disabled
Backplane Temp Fault disabled
Backplane Power Fault okay
Backplane Power A Fault disabled
Backplane Power B Fault disabled
Red Alarm Fault disabled
Blue Alarm Fault disabled
Yellow Alarm Fault disabled
Processor Temp Fault disabled
Ps Temp Fault disabled
Ps AC Fault disabled
Ps DC Fault disabled
Fan Temp Fault disabled
Fan Rotation Fault disabled
Local Pwr A Fault okay
Local Pwr B Fault disabled
Related Commands
■ chassis-fault on page 80