Technical information

ADC Telecommunications, Inc.
376 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
show aux-device
Displays the current power supply and fan tray fault report configuration, including which alarms
are sent out over the alarms out DB-15 connector on the rear chassis panel. The command also
displays clock sources for backplane clock A and backplane clock B.
Mode
root
Syntax
show aux-device {ac-monitor | backplane-clocks | db15 | dc-monitor |
fan-rotation | fan-temp | faults | ps-temp}
Arguments
ac-monitor Displays the assertion level configured for monitoring of AC power.
backplane-clocks Displays the sources for backplane clock A and backplane clock B.
Clock sources are none, bits-a, bits-b, and internal. The command
output also indicates whether the Stratum-3 oscillator is installed.
db15 Shows the alarms configured to be sent out over the alarms out DB-15
connector on the rear chassis panel. Note that a value of “enabled
indicates that the alarm is configured to be sent out over the DB-15
connector; a value of “disabled” indicates that it will not be sent over
the DB-15 connector.
dc-monitor Displays the assertion level configured for monitoring of DC power.
fan-rotation Displays the assertion level configured for monitoring the rotation of
fans within the fan tray unit.
fan-temp Displays the assertion level configured for the monitoring of the fan
tray temperature.
faults Displays the assertion level currently configured for all devices.
ps-temp Displays the assertion level configured for the monitoring of power
supply temperature.