Technical information

Cuda 12000 IP Access Switch CLI Reference Guide
pos report 317
pos report
Configures the POS interface to report selected SONET alarms to BASMONITOR. The plop,
sf-ber, slof, and slos SONET alarms are reported by default.
Use the no pos report command to disable logging of select SONET alarms.
Alarm reporting follows the SONET alarm hierarchy rules. Only the most severe alarm of an
alarm group is reported.
The following table lists the SONET Near-End Failure Alarm hierarchy:
The following table lists the SONET Far-End Failure Alarm hierarchy:
Mode
interface:pos:csi(<c/s/i>)
Syntax
pos report {lais|lrdi|pais|plop|prdi|sd-ber|sf-ber|slof|slos}
Table 2- 1 SONET Near-End Failure Alarm Hierarchy
Priority Near-End Failures
Highest LOS
LOF
LAIS
PAIS
PLOP
Table 2- 2 SONET Far-End Failure Alarm Hierarchy
Priority Near-End Failures
Highest LRDI
Lowest PRDI