Technical information

Cuda 12000 IP Access Switch CLI Reference Guide
no pos threshold 283
no pos threshold
Use this command to set the signal degrade Bit Error Rate (sd-BER) and signal fail Bit Error Rate
(sf-BER) thresholds back to their default values.
The default threshold value for the signal degrade BER is 6; default for Signal failure BER is 3.
When these thresholds are reached, the system sends the corresponding SONET alarm to the POS
controller.
You can view the defects that have been reported using the
show controllers command. To
configure these threshold values, use the pos threshold command.
Mode
interface:pos:csi(<c/s/i>)
Syntax
no pos threshold {sd-ber | sf-ber}
Arguments
Example
cli# interface 1/3/1
mode: interface:pos:csi(1/3/1)
cli# no pos threshold sf-ber
cli#
Related Commands
interface on page 181
pos threshold on page 321
show interface pos on page 437
sd-ber Sets the threshold for signal degradation BER errors on the current
interface back to the default value of 6.
sf-ber Sets the threshold for report signal failure BER errors on this interface
back to the default value of 3.