Technical information

Cuda 12000 IP Access Switch CLI Reference Guide
downstream transmit-power 155
downstream transmit-power
Configures the downstream transmit power on the selected CMTS card.
Mode
interface:cable:csi(<c/s/i>)
Syntax
downstream transmit-power <number>
Arguments
Example
The following example sets the downstream transmit power to 55.0 dBmV.
cli:172.16.19.10:root# interface 1/1/1
mode: interface:cable:csi(1/1/1)
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream transmit-power 550
cli:172.16.19.10:interface:cable:csi(1/1/1)#
Related Commands
downstream frequency on page 148
downstream interleave-depth on page 150
downstream modulation on page 151
downstream no shutdown on page 153
downstream shutdown on page 154
show interface cable <c/s/i> downstream on page 417
show downstream on page 403
<number> Number to which to set the downstream transmit power for the
current CMTS card. Acceptable values: 0 – 650. The value you
specify is then divided by ten. For example, if you specify 550,
then the real value is 55.0 dBmV.