Campus-REX RS Interface Card User Manual
Table Of Contents
- About the Product
- Installing theCampusREXRS InterfaceCard
- Set Up the CampusREXSystem
- Configuring andMonitoring throughthe LCD
- Configuring with an ASCII Terminal
- Setting Up and Logging On to an ASCIITerminal
- Logging Onto a Remote Campus Unit
- Logging Off of a Campus Unit
- Using the Terminal Menus
- Returning Configuration Options to Default Values
- Configuring the CampusREX for SNMP Management
- Configuring Startup Parameters
- Configuring the CampusREX as a Master or Slave Unit
- Configuring Alarms
- Entering System Information
- Configuring Loopbacks
- Updating the CampusREX Firmware
- Monitoring with anASCII Terminal
- Internetworking and Management Overview
- Technical Reference
- Abbreviations
- The Documentation Set
- Contacting ADC

Configuring and Monitoring through the LCD
4-8 Campus-REX RS Interface Card User Manual
Viewing Current Alarms
1 From the CURRENT ALARMS display, press Next until
HDSL LINK ALARMS displays.
2 Press Enter until the current HDSL alarm status displays.
3 Press Next until AUTOSYNC: displays.
4 If the AutoSync alarm is on or acknowledged, press Enter for more
information.
Configuring the Alarm
1 From the CURRENT ALARMS display, press Next until
HDSL LINK ALARMS displays.
2 Press Enter until the current HDSL alarm status displays.
3 Press Next until AUTOSYNC CFG ALM displays.
4 Press Enter.
5 Press Next to scroll through the settings for the AutoSync alarm until the
desired setting displays.
6 Press Enter to select the desired setting. AUTOSYNC CFG ALM
displays.
Local Alarms
Loss of Signal (LOS) alarms can occur on the local unit. This section
describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMS display indicates a local alarm, you can determine
the alarm type:
1 From the CURRENT ALARMS display, press Next twice. LOCAL I/F
ALARMS CONFIG & STATUS displays.
2 Press Enter. The current status of the local alarm displays.