Campus-REX RS Interface Card User Manual
Table Of Contents
- About the Product
- Installing theCampusREXRS InterfaceCard
- Set Up the CampusREXSystem
- Configuring andMonitoring throughthe LCD
- Configuring with an ASCII Terminal
- Setting Up and Logging On to an ASCIITerminal
- Logging Onto a Remote Campus Unit
- Logging Off of a Campus Unit
- Using the Terminal Menus
- Returning Configuration Options to Default Values
- Configuring the CampusREX for SNMP Management
- Configuring Startup Parameters
- Configuring the CampusREX as a Master or Slave Unit
- Configuring Alarms
- Entering System Information
- Configuring Loopbacks
- Updating the CampusREX Firmware
- Monitoring with anASCII Terminal
- Internetworking and Management Overview
- Technical Reference
- Abbreviations
- The Documentation Set
- Contacting ADC

Set Up the Campus-REX System
3-10 Campus-REX RS Interface Card User Manual
6 Press Next. HDSL RATE displays.
7 Press Enter.
8 Press Next until the desired HDSL transmission rate displays, then
press Enter.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
AutoSync HDSL Mode
This section continues from Step 4 in “Using the LCD” on page 3-8 to set the
Extended Mode parameters.
To configure AutoSync Mode, you must:
• Set the Transceiver Mode to Master or Slave.
• If the Transceiver Mode is set to Master, set the HDSL Loop Mode to
1 Loop or 2 Loop, depending on the physical layout of your HDSL
network.
• If the Transceiver Mode is set to Master, set the HDSL Rate to one of the
options determined by the HDSL Loop Mode:
– 1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
– 2 Loop HDSL Rate settings are between 256 kbps and 2.048 Mbps,
in 128 kbps increments.
1 With the LCD displaying OPERATING MODE, press Enter.
2 Press Next until AUTOSYNC displays, then press Enter.
OPERATING MODE displays. If you are configuring an AutoSync slave
system, skip the remainder of this section and proceed to “Configure the
Campus-REX as a Bridge or Router” on page 3-19. For an AutoSync
master system, continue with the remaining steps.
3 Press Next until XCVR MODE displays.
4 Press Enter.
5 Press Next until the MASTER displays, then press Enter. XCVR MODE
displays.
6 Press Next until LOOP MODE displays.
CAD1069i5.book Page 10 Thursday, May 30, 2002 7:32 AM