Datasheet
FS98O22
Rev. 1.6 52/146
Register TMOUT at address 0EH
property R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0
TMOUT
TMOUT [7:0]
Bit7 Bit0
Bit 7-0 TMOUT [7:0]: Timer module 8-bit counter output (Please refer to Section 6.1 for detail)
Register TMCON at address 0FH
property R/W-1 U-X U-X U-X R/W-0 R/W-0 R/W-0 R/W-0
TMCON
TRST TMEN INS [2:0]
Bit7 Bit0
Bit 7 TRST: Timer Module reset flag (Please refer to Section 6.1 for detail)
1 = Timer Module Counter works normally.
0 = Timer Module Counter is reset.(After resetting the Counter, TRST will reset itself)
Bit 3 TMEN: Timer Module enable flag (Please refer to Section 6.1 for detail)
1 = Timer Module Counter will active.
0 = Timer Module Counter will be disabled.
Bit 2-0 INS [2:0]: Timer Module interrupt Signal Selector (Please refer to Chapter 6.1 for detail)
111 = TMOUT[7] is selected as Timer Module interrupt Signal
110 = TMOUT[6] is selected as Timer Module interrupt Signal
101 = TMOUT[5] is selected as Timer Module interrupt Signal
100 = TMOUT[4] is selected as Timer Module interrupt Signal
011 = TMOUT[3] is selected as Timer Module interrupt Signal
010 = TMOUT[2] is selected as Timer Module interrupt Signal
001 = TMOUT[1] is selected as Timer Module interrupt Signal
000 = TMOUT[0] is selected as Timer Module interrupt Signal
property
R = Readable bit W = Writable bit U = unimplemented bit
- n = Value at Power On
Reset
‘1’ = Bit is Set ‘0’ = Bit is Cleared X = Bit is unknown
There are two timers in FS98O22: Timer Module and Watch Dog Timer. Please see the following sections for
detail.
FORTUNE'
Properties
For Reference Only