Datasheet

FS98O22
Rev. 1.6 37/146
4.4. Analog Common Voltage Generator
Figure 4-5 analog common voltage generator
Analog Common Voltage Generator is used to provide a voltage at the halt of AGND as 1/2 VDDA
6
. The
Control register is ENAGND and the output is AGND. Please see Figure 4-5.
Table 4-6 analog common voltage generator register table
Address Name
Referenced
Section
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Value on
Power on
Reset
1DH NETF 4/10/11 ENBAND ENVDDA ENAGND ENVB 00000000
Operation:
1. Operate following the steps Chapter 4.1 to get the VGG (2 times VDD or external Power Supply).
2. Operate as Section 4.2 to get the VDDA (3.6V)
3. Operate as Section 4.3 to activate the Analog Bias Circuit
4. Set the ENAGND register flag.
5. The output, AGND, will be 1/2 VDDA
6
When VDDA is 3.6V, AGND would be 1.8V
FORTUNE'