Datasheet

FS98O22
Rev. 1.6 129/146
Table 13-4 LCD driver register table
Address Name
Referenced
Section
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Value on
Power on
Reset
14H MCK 5 -- -- M5_CK M3_CK -- M1_CK M0_CK 00000000
40H LCD1 13 SEG2 [3:0] SEG1 [3:0] uuuuuuuu
41H LCD2 13 SEG4 [3:0] SEG3 [3:0] uuuuuuuu
42H LCD3 13 SEG6 [3:0] SEG5 [3:0] uuuuuuuu
43H LCD4 13 SEG8 [3:0] SEG7 [3:0] uuuuuuuu
44H LCD5 13 SEG10 [3:0] SEG9 [3:0] uuuuuuuu
45H LCD6 13 SEG12 [3:0] SEG11 [3:0] uuuuuuuu
46H LCD7 13 SEG14 [3:0] SEG13 [3:0] uuuuuuuu
47H LCD8 13 SEG16 [3:0] SEG15 [3:0] uuuuuuuu
48H LCD9 13 SEG18 [3:0] SEG17 [3:0] uuuuuuuu
49H LCD10 13 SEG20 [3:0] SEG19 [3:0] uuuuuuuu
54H LCDENR 13 LCDCKS [1:0] LCDEN LEVEL LCD_DUTY[1:0] ENPMPL 00000000
LCD operation
1. Connect the 20 segment ports and 4 common ports to LCD panel.
2. Setup LEVEL register flag to decide the LCD driver power system. (0 = 1/3 bias, 1 = 1/2 bias)
3. Set ENPMPL to enable the LCD charge pump.
4. Setup M0_CK,M1_CK,M3_CK and M5_CK to decide the LCD input clock frequency.(Refer to Section
5.7)
Table 13-5 CLK selection table
M1_CK
CL
K
0 MCK
1 MCK/4
Table 13-6 MCK selection table
M3_CK M0_CK
MCK
X 0 ICK
0 1 ECK
1 1 ECK/2
Table 13-7 TMCLK selection table
M5_CK TMCLK (Timer and LCD Module input Clock)
0 CLK/1000
1 ECK/32
5. Setup LCDCKS[1:0] register flags to decide the LCD Clock frequency.
FORTUNE'