Datasheet

FS98O22
Rev. 1.6 126/146
Register LCD4 at address 43H
property R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X
LCD4
SEG8 [3:0] SEG7 [3:0]
Bit7 Bit0
Bit 7-4 SEG8[3]: LCD driver control signal: SEG8 with COM4 data.
SEG8[2]: LCD driver control signal: SEG8 with COM3 data.
SEG8[1]: LCD driver control signal: SEG8 with COM2 data.
SEG8[0]: LCD driver control signal: SEG8 with COM1 data.
Bit 3-0 SEG7[3]: LCD driver control signal: SEG7 with COM4 data.
SEG7[2]: LCD driver control signal: SEG7 with COM3 data.
SEG7[1]: LCD driver control signal: SEG7 with COM2 data.
SEG7[0]: LCD driver control signal: SEG7 with COM1 data.
Register LCD5 at address 44H
property R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X
LCD5
SEG10 [3:0] SEG9 [3:0]
Bit7 Bit0
Bit 7-4 SEG10[3]: LCD driver control signal: SEG10 with COM4 data.
SEG10[2]: LCD driver control signal: SEG10 with COM3 data.
SEG10[1]: LCD driver control signal: SEG10 with COM2 data.
SEG10[0]: LCD driver control signal: SEG10 with COM1 data.
Bit 3-0 SEG9[3]: LCD driver control signal: SEG9 with COM4 data.
SEG9[2]: LCD driver control signal: SEG9 with COM3 data.
SEG9[1]: LCD driver control signal: SEG9 with COM2 data.
SEG9[0]: LCD driver control signal: SEG9 with COM1 data.
Property
R = Readable bit W = Writable bit U = unimplemented bit
- n = Value at Power On
Reset
‘1’ = Bit is Set ‘0’ = Bit is Cleared X = Bit is unknown
FORTUNE'
Properties
For Reference Only