Datasheet

FS98O22
Rev. 1.6 125/146
Register LCD2 at address 41H
property R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X
LCD2
SEG4 [3:0] SEG3 [3:0]
Bit7 Bit0
Bit 7-4 SEG4[3]: LCD driver control signal: SEG4 with COM4 data.
SEG4[2]: LCD driver control signal: SEG4 with COM3 data.
SEG4[1]: LCD driver control signal: SEG4 with COM2 data.
SEG4[0]: LCD driver control signal: SEG4 with COM1 data.
Bit 3-0 SEG3[3]: LCD driver control signal: SEG3 with COM4 data.
SEG3[2]: LCD driver control signal: SEG3 with COM3 data.
SEG3[1]: LCD driver control signal: SEG3 with COM2 data.
SEG3[0]: LCD driver control signal: SEG3 with COM1 data.
Register LCD3 at address 42H
property R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X R/W-X
LCD3
SEG6 [3:0] SEG5 [3:0]
Bit7 Bit0
Bit 7-4 SEG6[3]: LCD driver control signal: SEG6 with COM4 data.
SEG6[2]: LCD driver control signal: SEG6 with COM3 data.
SEG6[1]: LCD driver control signal: SEG6 with COM2 data.
SEG6[0]: LCD driver control signal: SEG6 with COM1 data.
Bit 3-0 SEG5[3]: LCD driver control signal: SEG5 with COM4 data.
SEG5[2]: LCD driver control signal: SEG5 with COM3 data.
SEG5[1]: LCD driver control signal: SEG5 with COM2 data.
SEG5[0]: LCD driver control signal: SEG5 with COM1 data.
Property
R = Readable bit W = Writable bit U = unimplemented bit
- n = Value at Power On
Reset
‘1’ = Bit is Set ‘0’ = Bit is Cleared X = Bit is unknown
FORTUNE'
Properties
For Reference Only