Datasheet

FS98O22
Rev. 1.6 106/146
Register NETB at address 19H
property U-0 U-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
NETB
SOP1N[1:0] SVRL[1:0] SVRH[1:0]
Bit7 Bit0
Bit 5-4 SOP1N[1:0]: OPAMP inverting input port signal multiplexer (Please refer to Section 10.2)
11 = The OPAMP inverting input port is connected to AIN6 (PT1[3]).
10 = The OPAMP inverting input port is connected to AIN5 (PT1[5]).
01 = The OPAMP inverting input port is connected to AIN4 (PT1[4]).
00 = The OPAMP inverting input port is connected to OP1O (OPAMP output port).
Bit 3-2 SVRL[1:0]: ADC reference voltage negative input port signal multiplexer (Please refer to Section
10.1)
11 = The ADC negative referenced input port is connected to VR2P (1/5 REFO
25
).
10 = The ADC negative referenced input port is connected to AIN2 (PT1[2]).
01 = The ADC negative referenced input port is connected to AIN1 (PT1[1]).
00 = The ADC negative referenced input port is connected to AGND (Please refer to Section 4.4).
Bit 1-0 SVRH[1:0]: ADC reference voltage positive input port signal multiplexer (Please refer to Section
10.1)
11 = The ADC negative referenced input port is connected to VR2P (1/5 REFO).
10 = The ADC negative referenced input port is connected to VR1P (2/5 REFO).
01 = The ADC negative referenced input port is connected to AIN3 (PT1[3]).
00 = The ADC negative referenced input port is connected to AIN0 (PT1[0]).
Property
R = Readable bit W = Writable bit U = unimplemented bit
- n = Value at Power On Reset ‘1’ = Bit is Set ‘0’ = Bit is Cleared X = Bit is unknown
25
Please refer to Section 4.6 for REFO detailed information
FORTUNE'
Properties
For Reference Only