Installation manual

65
b) Fault in blower (impellor/fan) motor circuit (for reversing models only).
2. Tripped manual reset burner hi-limit.
3. Tripped manual reset basket (tumbler) hi-limit.
ELECTRIC MODELS...
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment or has failed.
b. Sail switch damper is not closing or is fluttering...
1) Lint screen is dirty.
2) Restriction in the exhaust ductwork.
3) No exhaust airflow...
a) Failed impellor (fan/blower).
b) Fault in blower (impellor/fan) motor circuit (for reversing models only).
c. Failed oven hi-limit.
d. Tripped manual reset basket (tumbler) hi-limit.
e. Failed temperature selection switch or circuit.
f. Failed temperature cycle thermostat (try another selection).
STEAM MODELS...
1. Tripped manual reset basket (tumbler) hi-limit.
2. Failed temperature selection switch or circuit.
3. Failed temperature cycle thermostat (try another selection).
4. Failed heat timer.
I. No heat...voltage is evident at heating unit (i.e., gas model - Direct Spark Ignition [DSI], module,
electric model - electric oven contactor, or steam model - steam damper system pneumatic
solenoid)...
GAS MODELS...
1. Fault in DSI system...
a. Ignitor sparks but no ignition and module locks out (“GREEN” indicator flashes)...