Installation manual
63
9. Failed motor bearing.
DUAL TIMER MODELS
A. Dryer will not start, both drive motor and blower (impellor/fan) motor are not operating (DO
NOT start) and indicator light is off...
1. Service panel fuse blown or tripped breaker.
2. Dryer control circuit L1 or L2 1/2-amp (slo blo) fuse is blown.
3. Open in main door switch...
a. Main door is not closed ALL the way.
b. Main door switch is out of proper adjustment.
c. Failed main door switch.
d. Broken connection/wire somewhere in the main door switch circuit.
4. Failed push-to-start relay.
5. Failed 24 VAC step down transformer or a fault in the wiring.
6. Failed heat timer.
7. Failed control step down transformer (for 380 volts or higher models only).
B. Drive motor is not operating (does not start)...
1. Failed drive motor contactor (relay).
2. Failed reversing timer (for reversing models only).
3. Failed drive motor.
C. Drive motor (for reversing models only) operates in one (1) direction only, stops and restarts in
the same direction...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
D. Drive motor operates okay for a few minutes, then stops and will not restart...
1. Motor is overheating and tripping out on internal overload protector...
a. Motor air vents clogged with lint.