b) Restriction in exhaust ductwork.
c. Ignitor does not spark and module locks out (“RED” indicator stays on).
1) Fault in high voltage (HV) wire, break or loose connection.
2) Failed ignitor probe assembly.
3) Failed Direct Spark Ignition (DSI) module.
ELECTRIC MODELS...
1. Failed oven contactor/coil.
2. Failed electric heating element(s).
STEAM MODELS...
1. Air Operated System...
a. No (external) compressed air (80 PSI [5.51 bars] is required) to steam damper solenoid.
b. Failed steam damper pneumatic solenoid.
c. Steam damper stuck in closed position, check for obstruction.
d. Leak in pneumatic system.
e. Failed steam damper air piston.
f. Flow control valve misadjusted.
2. Electrical Mechanical System...
a. Failed electrical mechanical motor.
b. Steam damper stuck in closed position, check for obstruction.
W. Dryer operates but is taking too long to dry...
1. Exhaust ductwork run is too long or is undersized, back pressure must be no less than 0 and cannot
exceed 0.3 inches (0.74 mb) water column (W.C.).
2. Restriction in exhaust ductwork...
a. Dryer back draft damper is sticking partially closed.
b. Restriction/obstruction in ductwork...
1) Check ductwork from the dryer ALL the way to the outdoors.
3. Insufficient make-up air.