User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Maximum Output Power Per Carrier at RAU
6-10 InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL D-620003-0-20 Rev K
6.1.8 700 MHz Public Safety
Table 6-8 Public Safety 700 MHz Power per Carrier
No. of
Carriers
Power per Carrier (dBm)
iDEN
APCO25
CQPSK
APCO25
C4FM
CDMA
2000 WCDMA
1 10.0 10.0 10.0 16.0 15.0 Max. composite DL
2
10.0 10.0 10.0 13.0 11.0
3
10.0 10.0 10.0 11.0 8.0
4
10.0 10.0 10.0 10.0 6.5
5
9.0 10.0 10.0 9.0 5.0
6
8.0 9.5 10.0 8.0
7
7.0 9.0 9.0 7.5
8
6.5 8.0 8.5 7.0
9
6.0 7.5 7.5
10
5.5 7.0 7.0
Note: Operation at or above these output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and EN55022
emissions requirements. Refer to the Unison Installation, Operation, and Reference manual for system design information.
Table 6-9 900 MHz Paging/SMR/iDEN
No. of
Carriers
Power per Carrier (dBm)
iDEN
2 km SMF
1 km MMF
Analog
FM
2 km SMF
1 km MMF
CQPSK
2 km SMF
1 km MMF
C4FM
2 km SMF
1 km MMF
Mobitex
2 km SMF
1 km MMF
POCSAG/
REFLEX
2 km SMF
1 km MMF
1 17.5 26.0 22.0 26.0 26.0 26.0
2
14.0 19.5 17.0 19.5 19.5 19.5
3
11.5 16.5 14.5 16.0 16.0 16.0
4
10.0 13.5 12.5 13.5 13.5 13.5
5
9.0 12.0 11.0 11.5
6
8.0 10.5 9.5 10.0
7
7.0 9.5 9.0 9.0
8
6.5 8.5 8.0 8.5
9
6.0 8.0 7.5 7.5
10
5.5 7.0 7.0 7.0
Note: Operation at or above the output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and
EN55022 emissions requirements. Refer to the Unison Installation, Operation, and Reference manual for system design information.