User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Help Hot Line (U.S. only): 1-800-530-9960 6-5
D-620003-0-20 Rev K CONFIDENTIAL
Maximum Output Power Per Carrier at RAU
6.1.2 800 MHz iDEN/SMR
Table 6-2 iDEN/SMR Power per Carrier
No. of
Carriers
Power per Carrier (dBm)
iDEN
2 km SMF/
1 km MMF
Analog FM
2 km SMF/
1 km MMF
CQPSK
2 km SMF/
1 km MMF
C4FM
2 km SMF/
1 km MMF
Motient Data
TAC
2 km SMF/
1 km MMF
1 10.0 10.0 10.0 10.0 10.0
2
10.0 10.0 10.0 10.0 10.0
3
10.0 10.0 10.0 10.0 10.0
4
10.0 10.0 10.0 10.0 10.0
5
9.0 10.0 10.0 10.0
6
8.0 10.0 9.5 10.0
7
7.0 9.5 9.0 9.0
8
6.5 8.5 8.0 8.5
9
6.0 8.0 7.5 7.5
10
5.5 7.0 7.0 7.0
Note: Operation at or above these output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and EN55022 emis-
sions requirements. Refer to the Unison Installation, Operation, and Reference manual for system design information.