User's Manual

Table Of Contents
Maximum Output Power Per Carrier at RAU
6-4 InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL D-620003-0-20 Rev K
6.1.1 800 MHz Cellular
Table 6-1 Cellular Power per Carrier
No. of
Carriers
Power per Carrier (dBm)
AMPS
2 km SMF/
1 km MMF
TDMA
2 km SMF/
1 km MMF
GSM
2 km SMF
GSM
1 km MMF
EDGE
2 km SMF
EDGE
1 km MMF
CDMA
2 km SMF/
1 km MMF
1 27.0 24.0 27.0 27.0 24.0 24.0 17.0
2
21.0 19.0 14.5 12.5 14.5 12.5 14.0
3
17.5 16.0 12.5 10.5 12.5 10.5 12.0
4
14.5 14.0 11.5 9.5 11.5 9.5 11.0
5
13.0 12.5 10.5 8.5 10.5 8.5 10.0
6
11.5 11.5 9.5 7.5 9.5 7.5 9.0
7
10.5 10.5 9.0 7.0 9.0 7.0 8.5
8
9.5 9.5 8.5 6.5 8.5 6.5 8.0
9
9.0 9.0 8.5 6.5 8.5 6.5
10
8.0 8.5 8.0 6.0 8.0 6.0
11
8.0 8.0 7.5 5.5 7.5 5.5
12
7.5 7.5 7.5 5.5 7.0 5.5
13
7.0 7.5 7.0 5.0 7.0 5.0
14
6.5 7.0 7.0 5.0 6.5 5.0
15
6.5 6.5 6.5 4.5 6.0 4.5
16
6.0 6.5 6.5 4.5 6.0 4.5
20
5.0 5.5 5.5 3.5 5.0 3.5
30
3.0 3.5 4.0 2.0 3.0 2.5
Note: Operation at or above these output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and EN55022 emis-