User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Expansion Hub Specifications
4-8 InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL D-620003-0-20 Rev K
4.4 Expansion Hub Specifications
Table 4-4 Expansion Hub Specifications
Specification Description
Enclosure Dimensions (H
× W × D) 89 mm × 438 mm × 305 mm (3.5 in. × 17.25 in. × 12 in.)
2U
Weight < 5 kg (< 11 lb)
Operating Temperature
c
0° to +45°C (+32° to +113°F)
Non-operating Temperature
c
–20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing 5% to 95%
Cat-5/5E/6 Connectors
a
a. It is important that you use only Cat-5/5E/6 ScTP cable with shielded RJ-45 connectors.
8 shielded RJ-45, female (Cat-5/6)
Fiber Connectors
b
b. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including
fiber distribution panels.
c. For Japan, see separate addendum - Japan Specification Document.
1 Pair, SC/APC
LED Alarm and Status Indicators Unit Status (1 pair):
•Power
• E-Hub Status
Fiber Link Status (1 pair):
•DL Status
•UL Status
RAU/Link Status (1 pair per RJ-45 port):
•Link
•RAU
AC Power (Volts) (47–63 Hz) Rating: 115/230V, 5/2.5A, 50–60 Hz
Operating Range: 90–132V/170–250V auto-ranging,
2.2–1.5A/1.2–0.8A, 47–63 Hz
Power Consumption (W) 4 RAUs: 120 typical/148 max
4 RAUs & 4 Extenders: 137 typical/172 max
8 RAUs: 170 typical/212 max
8 RAUs & 8 Extenders: 204 typical/260 max
MTBF 92,820 hours