User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Help Hot Line (U.S. only): 1-800-5 30-9960 4-5
D-620003-0-20 Rev K CONFIDENTIAL
Expansion Hub Front Panel
Port LEDs
The Expansion Hub has one pair of port LEDs for each of the eight RJ-45 ports. The
port LEDs can be in one of the states shown in Table 4-2. These LEDs can be:
off
steady green
steady red
Green / Red
Green / Red
• Expansion Hub is in factory test mode, return it to the factory.
Red/ Red
Red/ Red
• One or more power supplies are out of specification. The hub needs to
be replaced.
Table 4-2 Expansion Hub Port LED States
LED State Indicates
Off
Off
• The RAU is not connected.
Green
Green
• The RAU is connected.
• No faults from the RAU.
Red
Off
• The RAU was disconnected.
• The RAU is not communicating.
• The RAU port power is tripped.
• 36 VDC is shutdown due to an EH over-temperature condition.
Green
Red
• The RAU is connected.
• The RAU is reporting a fault or lockout condition.
Table 4-1 Expansion Hub Unit Status and DL/UL Status LED States
LED State Indicates
POWER
E-HUB STATUS
DL STATUS
UL STATUS
POWER
E-HUB STATUS
DL STATUS
UL STATUS
LINK
RAU
LINK
RAU
LINK
RAU
LINK
RAU