User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Help Hot Line (U.S. only): 1-800-5 30-9960 9-31
D-620003-0-20 Rev K CONFIDENTIAL
Troubleshooting CAT-5/5E/6
9.4 Troubleshooting CAT-5/5E/6
Refer to Table A-1 on page A-1 for a description of the CAT-5/5E/6 wire assignment.
The following table summarizes
CAT-5/5E/6 problems if a wire is cut or not wired
properly.
Table 9-14 Summary of Cat-5/5E/6 Cable Wiring Problems
Type of
problem Message Icon Icon* Impact
Wire 1 or 2 cut None High phase noise, degraded signal on both
Downlink and Uplink (high bit error rate)
Wire 3 or 6 cut • No communication with RAUn RAU unable to communicate with EH,
decreased UL gain, or no UL gain
Wire 4 or 5 cut • Portn UL RF path loss is too high Increased ripple in the uplink path,
decreased UL gain, or no UL gain
• Portn UL RF path loss is higher
than recommended
Wire 7 or 8 cut • The DL RF path loss is too high Increased ripple in the downlink path,
RAU off-line
• The DL RF path loss is higher than
recommended
Wire 1 to RJ-45
pin 3 or 6
• No communication with RAUn RAU unable to communicate with EH,
RAU’s RS-485 port damaged, degraded
performance or RAU off-line
Wire 1 to RJ-45
pin 4, 5, 7 or 8
•RAUn over current RAU will not power on.
Wire 2 to RJ-45
pin 3 or 6
• No communication with RAUn RAU unable to communicate with EH,
RAU’s RS-485 port damaged, degraded
performance or RAU off-line
Wire 2 to RJ-45
pin 4, 5, 7 or 8
•RAUn over current RAU will not power on
Wire 3 to RJ-45
pin 4, 5, 7 or 8
• No communication with RAUn RAU unable to communicate with EH,
degraded performance or RAU off-line
Wire 6 to RJ-45
pin 4, 5, 7 or 8
• No communication with RAUn RAU unable to communicate with EH,
degraded performance or RAU off-line
Wire 4 to RJ-45
pin 7 or 8
• Portn UL RF path loss is too high Increased ripple in the downlink and
uplink path, degraded performance or
RAU off-line
• Portn UL RF path loss is higher
than recommended
• The DL RF path loss is too high
• The DL RF path loss is higher than
recommended