User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Troubleshooting
9-12 InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL D-620003-0-20 Rev K
{EF27} Port 3 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF28} Port 4 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF29} Port 5 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF30} Port 6 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF31} Port 7 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF32} Port 8 UL RF path loss is too high CAT-5 cable is poorly terminated, re-crimp the connector; no RF uplink is
detected at all.
Check Cat-5E/6 cable loss, especially on new install. Check Cat-5 Extender, if
present. If fault present on all EH ports, replace the EH. Otherwise, try another
EH port. If no fault is reported, flag the previous port as unusable and replace
the EH when possible. Otherwise, replace the RAU.
{EF33}Port 1 DL RF path too low Try another port, if fault persists replace the EH. Otherwise, flag previous port
as unusable and replace the EH when possible
{EF34}Port 2 DL RF path too low Try another port, if fault persists replace the EH. Otherwise, flag previous port
as unusable and replace the EH when possible
{EF35}Port 3 DL RF path too low Try another port, if fault persists replace the EH. Otherwise, flag previous port
as unusable and replace the EH when possible
{EF36}Port 4 DL RF path too low Try another port, if fault persists replace the EH. Otherwise, flag previous port
as unusable and replace the EH when possible
Table 9-2 Faults Reported by the Expansion Hub (continued)