User's Manual

Table Of Contents
Help Hot Line (U.S. only): 1-800-5 30-9960 9-9
D-620003-0-20 Rev K CONFIDENTIAL
Troubleshooting
{MF47}EH 3 disconnected Try another port. If no connection, cycle EH power and confirm UL STATUS
LED is green for 90 seconds. Check UL fiber connection(s). Clean fiber con-
nectors and ports on MH and EH. Measure UL optical loss. Use “Clear All Dis-
connect Status” command to clear fault, or physically connect the EH.
{MF48}EH 4 disconnected Try another port. If no connection, cycle EH power and confirm UL STATUS
LED is green for 90 seconds. Check UL fiber connection(s). Clean fiber con-
nectors and ports on MH and EH. Measure UL optical loss. Use “Clear All Dis-
connect Status” command to clear fault, or physically connect the EH.
Table 9-1 Faults Reported by the Main Hub (continued)